Winlink - In preparation to support VARA FM and HF, I started to refactor the Winlink modes. Added support for Winlink configuration templates. Added supported for native AX.25 packet for devices that use /dev/rfcomm0 and a Bluetooth TNC
This commit is contained in:
@@ -0,0 +1,19 @@
|
||||
# Author : Gaston Gonzalez
|
||||
# Date : 3 February 2025
|
||||
# Purpose : User systemd unit file for EmComm Tools Winlink over packet
|
||||
#
|
||||
# Usage:
|
||||
# Check status : systemctl --user status et-service-winlink-native-packet
|
||||
# Start service : systemctl --user start et-service-winlink-native-packet
|
||||
# Stop service : systemctl --user stop et-service-winlink-native-packet
|
||||
# Reload this config : systemctl --user daemon-reload
|
||||
|
||||
[Unit]
|
||||
Description=EmComm Tools Winlink native AX.25 packet service
|
||||
|
||||
[Service]
|
||||
ExecStart=/opt/emcomm-tools/bin/et-winlink start-native-packet
|
||||
Restart=no
|
||||
|
||||
[Install]
|
||||
WantedBy=multi-user.target
|
||||
@@ -2,7 +2,7 @@
|
||||
#
|
||||
# Author : Gaston Gonzalez
|
||||
# Date : 12 November 2024
|
||||
# Updated : 13 January 2025
|
||||
# Updated : 3 February 2025
|
||||
# Purpose : Stops all EmComm Tools sound-based services (i.e. modems) and
|
||||
# amatuer radio applications to ensure a clean start for the next mode.
|
||||
|
||||
@@ -11,6 +11,7 @@
|
||||
stop_all_services() {
|
||||
systemctl --user stop et-service-winlink-ardop
|
||||
systemctl --user stop et-service-winlink-packet
|
||||
systemctl --user stop et-service-winlink-native-packet
|
||||
systemctl --user stop et-service-ardop
|
||||
systemctl --user stop et-service-direwolf-300
|
||||
systemctl --user stop et-service-direwolf-9600
|
||||
|
||||
@@ -2,7 +2,7 @@
|
||||
#
|
||||
# Author : Gaston Gonzalez
|
||||
# Date : 6 November 2024
|
||||
# Updated : 14 January 2025
|
||||
# Updated : 3 February 2025
|
||||
# Purpose : Configures the system for a specific mode of operation
|
||||
|
||||
# Use a simple text file to save the state of the last mode selected
|
||||
@@ -87,6 +87,18 @@ select_direwolf_mode () {
|
||||
fi
|
||||
}
|
||||
|
||||
select_winlink_mode () {
|
||||
winlink_mode=()
|
||||
|
||||
BLUETOOTH_TNC_CHECK=$(ps -ef | grep "[r]fcomm connect")
|
||||
if [[ $? -eq 0 ]]; then
|
||||
et-log "AX.25 over Bluetooth connected. Configuring Winlink for native AX.25"
|
||||
start_and_wait_for_service et-service-winlink-native-packet
|
||||
min http://localhost:8080
|
||||
exit 0
|
||||
fi
|
||||
}
|
||||
|
||||
# Build list of options
|
||||
options=()
|
||||
options+=("${MODE_ID_NONE}" "No mode selected")
|
||||
@@ -150,11 +162,13 @@ if [ $exit_status -eq 0 ]; then
|
||||
et-log "Packet digipeater now running."
|
||||
;;
|
||||
${MODE_ID_WINLINK_ARDOP})
|
||||
et-log "Using ${PACKET_MODE} as the modem speed."
|
||||
start_and_wait_for_service et-service-ardop
|
||||
start_and_wait_for_service et-service-winlink-ardop
|
||||
min http://localhost:8080
|
||||
;;
|
||||
${MODE_ID_WINLINK_PACKET})
|
||||
select_winlink_mode
|
||||
start_and_wait_for_service et-service-direwolf-simple
|
||||
start_and_wait_for_service et-service-winlink-packet
|
||||
min http://localhost:8080
|
||||
|
||||
@@ -2,7 +2,7 @@
|
||||
#
|
||||
# Author : Gaston Gonzalez
|
||||
# Date : 11 October 2024
|
||||
# Updated : 14 December 2024
|
||||
# Updated : 3 February 2025
|
||||
# Purpose : A script for managaing plug-and-play radios
|
||||
set -e
|
||||
|
||||
@@ -48,6 +48,13 @@ if [ $exit_status -eq 0 ]; then
|
||||
VENDOR=$(cat ${ACTIVE_RADIO} | jq -r .vendor)
|
||||
MODEL=$(cat ${ACTIVE_RADIO} | jq -r .model)
|
||||
|
||||
BLUETOOTH_TNC_CHECK=$(ps -ef | grep "[r]fcomm connect")
|
||||
if [[ $? -eq 0 ]]; then
|
||||
et-log "Killing running processes for Bluetooth TNC"
|
||||
sudo killall kissattach
|
||||
sudo killall rfcomm
|
||||
fi
|
||||
|
||||
printf "%-20s %-10s %-10s\n" "Radio ID" "Vendor" "Model"
|
||||
printf "%-20s %-10s %-10s\n\n" $ID "$VENDOR" "$MODEL"
|
||||
|
||||
@@ -55,7 +62,6 @@ if [ $exit_status -eq 0 ]; then
|
||||
cat ${ACTIVE_RADIO} | jq -r '.notes[] | "* \(.)"'
|
||||
echo -e "${NC}"
|
||||
|
||||
|
||||
printf "${GREEN}REQUIRED ACTIONS\n"
|
||||
printf "1. Apply the settings above to your radio.\n"
|
||||
printf "2. Plug in the USB cable for your radio. If it is already\n"
|
||||
|
||||
@@ -2,14 +2,14 @@
|
||||
#
|
||||
# Author : Gaston Gonzalez
|
||||
# Date : 1 January 2025
|
||||
# Updated : 3 January 2025
|
||||
# Updated : 3 February 2025
|
||||
# Purpose : Utility for accessing the Bluetooth TNC on the BTECH
|
||||
# UV PRO.
|
||||
|
||||
ACTIVE_RADIO="${ET_HOME}/conf/radios.d/btech-uvpro.bt.json"
|
||||
DEVICE_NAME="UV-PRO"
|
||||
BT_DEVICE="/dev/rfcomm0"
|
||||
AX25_PORT="pkt1200"
|
||||
AX25_PORT="wl2k"
|
||||
AX25_CONF_FILE="/etc/ax25/axports"
|
||||
|
||||
ESC="\x1B"
|
||||
@@ -78,15 +78,15 @@ update_ax25_conf() {
|
||||
|
||||
GREP_OUT=$(grep ${AX25_PORT} ${AX25_CONF_FILE})
|
||||
if [ $? -eq 0 ]; then
|
||||
# Delete all existing pkt1200 entries. Note: we can't use sed here
|
||||
# Delete all existing AX.25 port entries. Note: we can't use sed here
|
||||
# since we do not have permission to create a temporary file with
|
||||
# inline replacement. ed modifies the file directly.
|
||||
printf "g/^pkt1200/d\nw\nq\n" | ed ${AX25_CONF_FILE} > /dev/null 2>&1
|
||||
printf "g/^${AX25_PORT}/d\nw\nq\n" | ed ${AX25_CONF_FILE} > /dev/null 2>&1
|
||||
|
||||
fi
|
||||
|
||||
info_message "Adding AX25 port for ${CALLSIGN}"
|
||||
echo "pkt1200 ${CALLSIGN} 1200 255 2 1200 Packet" >> ${AX25_CONF_FILE}
|
||||
echo "${AX25_PORT} ${CALLSIGN} 1200 255 2 1200 Packet" >> ${AX25_CONF_FILE}
|
||||
}
|
||||
|
||||
stop_all_services() {
|
||||
@@ -235,8 +235,8 @@ EOF
|
||||
echo -e "${YELLOW}"
|
||||
echo -e "SAMPLE COMMANDS DESCRIPTION "
|
||||
echo -e "------------------------------- --------------------------------"
|
||||
echo -e "axcall pkt1200 <STATION> Connect directly to a node "
|
||||
echo -e "axcall pkt1200 <STATION> <DIGI> Connect to node via a digipeater"
|
||||
echo -e "axcall ${AX25_PORT} <STATION> Connect directly to a node "
|
||||
echo -e "axcall ${AX25_PORT} <DIGI> Connect to node via a digipeater"
|
||||
echo -e "sudo axlisten -a -tttt -c Monitor inbound and outbound traffic"
|
||||
echo -e "${NC}"
|
||||
|
||||
|
||||
@@ -2,7 +2,7 @@
|
||||
#
|
||||
# Author : Gaston Gonzalez
|
||||
# Date : 4 November 2024
|
||||
# Updated : 12 December 2024
|
||||
# Updated : 3 February 2025
|
||||
# Purpose : Wrapper script for starting YAAC with PnP support
|
||||
#
|
||||
# Preconditions:
|
||||
@@ -13,14 +13,17 @@
|
||||
# 1. Callsign, Winlink password, and grid are updated are updated
|
||||
# 2. pat http is started
|
||||
|
||||
source /opt/emcomm-tools/bin/et-common
|
||||
|
||||
PAT_CONF_FILE=${HOME}/.config/pat/config.json
|
||||
PAT_CONF_FILE_TEMPLATE=/etc/skel/.config/pat/config.json
|
||||
|
||||
usage() {
|
||||
echo "usage: $(basename $0) <command>"
|
||||
echo " <command>"
|
||||
echo " start-ardop - Start Pat Winlink in ardop mode"
|
||||
echo " start-packet - Start Pat Winlink in packet mode"
|
||||
echo " start-ardop - Start Pat Winlink in ardop mode"
|
||||
echo " start-packet - Start Pat Winlink in packet mode"
|
||||
echo " start-native-packet - Start Pat Winlink in native AX.25 packet mode"
|
||||
}
|
||||
|
||||
if [ $# -ne 1 ]; then
|
||||
@@ -60,7 +63,7 @@ start_packet() {
|
||||
notify_user "Dire Wolf not running. Run: et-direwolf simple-packet"
|
||||
exit 1
|
||||
fi
|
||||
|
||||
|
||||
update_config packet
|
||||
|
||||
CMD="pat http"
|
||||
@@ -69,6 +72,24 @@ start_packet() {
|
||||
${CMD}
|
||||
}
|
||||
|
||||
# Only the BTECH UV PRO is supported in this mode
|
||||
start_native_packet() {
|
||||
|
||||
BLUETOOTH_TNC_CHECK=$(ps -ef | grep "[r]fcomm connect")
|
||||
if [[ $? -ne 0 ]]; then
|
||||
echo -e "${RED}Can't start Pat in native AX.25 packet mode."
|
||||
echo -e "If you have a UV Pro, first run: ${YELLOW}et-uv-pro connect${NC}"
|
||||
exit 1
|
||||
fi
|
||||
|
||||
update_config native-packet
|
||||
|
||||
CMD="pat http"
|
||||
et-log "Starting Pat with: ${CMD}"
|
||||
|
||||
${CMD}
|
||||
}
|
||||
|
||||
update_config () {
|
||||
|
||||
[ -z "$ET_USER_CONFIG" ] && ET_USER_CONFIG="${HOME}/.config/emcomm-tools/user.json"
|
||||
@@ -82,6 +103,18 @@ update_config () {
|
||||
exit 1
|
||||
fi
|
||||
|
||||
case $1 in
|
||||
ardop)
|
||||
PAT_CONF_FILE_TEMPLATE=/opt/emcomm-tools/conf/template.d/winlink/config.ardop.json
|
||||
;;
|
||||
packet)
|
||||
PAT_CONF_FILE_TEMPLATE=/opt/emcomm-tools/conf/template.d/winlink/config.ax25-agw.json
|
||||
;;
|
||||
native-packet)
|
||||
PAT_CONF_FILE_TEMPLATE=/opt/emcomm-tools/conf/template.d/winlink/config.ax25-native.json
|
||||
;;
|
||||
esac
|
||||
|
||||
et-log "Updating Pat configuration file: ${PAT_CONF_FILE}..."
|
||||
cp -v ${PAT_CONF_FILE_TEMPLATE} ${PAT_CONF_FILE}
|
||||
|
||||
@@ -89,15 +122,6 @@ update_config () {
|
||||
sed -i "s|{{ET_WINLINK_PASSWD}}|${WINLINK_PASSWD}|g" ${PAT_CONF_FILE}
|
||||
sed -i "s|{{ET_GRID}}|${GRID}|g" ${PAT_CONF_FILE}
|
||||
|
||||
# Enable the P2P listener for the current mode selected (ARDOP or AX.25)
|
||||
case $1 in
|
||||
ardop)
|
||||
sed -i "s|{{ET_WINLINK_LISTEN}}|ardop|g" ${PAT_CONF_FILE}
|
||||
;;
|
||||
packet)
|
||||
sed -i "s|{{ET_WINLINK_LISTEN}}|ax25|g" ${PAT_CONF_FILE}
|
||||
;;
|
||||
esac
|
||||
}
|
||||
|
||||
case $1 in
|
||||
@@ -107,6 +131,9 @@ case $1 in
|
||||
start-packet)
|
||||
start_packet
|
||||
;;
|
||||
start-native-packet)
|
||||
start_native_packet
|
||||
;;
|
||||
*)
|
||||
echo "Invalid command."
|
||||
usage
|
||||
|
||||
@@ -0,0 +1,83 @@
|
||||
{
|
||||
"mycall": "{{ET_CALLSIGN}}",
|
||||
"secure_login_password": "{{ET_WINLINK_PASSWD}}",
|
||||
"auxiliary_addresses": [],
|
||||
"locator": "{{ET_GRID}}",
|
||||
"service_codes": [
|
||||
"PUBLIC"
|
||||
],
|
||||
"http_addr": "localhost:8080",
|
||||
"motd": [
|
||||
"Open source Winlink client - getpat.io"
|
||||
],
|
||||
"connect_aliases": {
|
||||
"telnet": "telnet://{mycall}:CMSTelnet@cms.winlink.org:8772/wl2k"
|
||||
},
|
||||
"listen": [ "ardop" ],
|
||||
"hamlib_rigs": {
|
||||
"et-rig": {
|
||||
"address": "localhost:4532",
|
||||
"network": "tcp"
|
||||
}
|
||||
},
|
||||
"ax25": {
|
||||
"engine": "agwpe",
|
||||
"beacon": {
|
||||
"every": 3600,
|
||||
"message": "Winlink P2P",
|
||||
"destination": "IDENT"
|
||||
},
|
||||
"agwpe": {"addr": "localhost:8000", "radio_port": 0}
|
||||
},
|
||||
"serial-tnc": {
|
||||
"path": "/dev/ttyUSB0",
|
||||
"serial_baud": 9600,
|
||||
"hbaud": 1200,
|
||||
"type": "Kenwood"
|
||||
},
|
||||
"ardop": {
|
||||
"addr": "localhost:8515",
|
||||
"arq_bandwidth": {
|
||||
"Forced": false,
|
||||
"Max": 500
|
||||
},
|
||||
"rig": "et-rig",
|
||||
"ptt_ctrl": true,
|
||||
"beacon_interval": 0,
|
||||
"cwid_enabled": true
|
||||
},
|
||||
"pactor": {
|
||||
"path": "/dev/ttyUSB0",
|
||||
"baudrate": 57600,
|
||||
"rig": "",
|
||||
"custom_init_script": ""
|
||||
},
|
||||
"telnet": {
|
||||
"listen_addr": ":8774",
|
||||
"password": ""
|
||||
},
|
||||
"varahf": {
|
||||
"host": "localhost",
|
||||
"cmdPort": 8300,
|
||||
"dataPort": 8301,
|
||||
"bandwidth": 2300,
|
||||
"rig": "",
|
||||
"ptt_ctrl": false
|
||||
},
|
||||
"varafm": {
|
||||
"host": "localhost",
|
||||
"cmdPort": 8300,
|
||||
"dataPort": 8301,
|
||||
"bandwidth": 0,
|
||||
"rig": "",
|
||||
"ptt_ctrl": false
|
||||
},
|
||||
"gpsd": {
|
||||
"enable_http": false,
|
||||
"allow_forms": false,
|
||||
"use_server_time": false,
|
||||
"addr": "localhost:2947"
|
||||
},
|
||||
"schedule": {},
|
||||
"version_reporting_disabled": false
|
||||
}
|
||||
@@ -0,0 +1,83 @@
|
||||
{
|
||||
"mycall": "{{ET_CALLSIGN}}",
|
||||
"secure_login_password": "{{ET_WINLINK_PASSWD}}",
|
||||
"auxiliary_addresses": [],
|
||||
"locator": "{{ET_GRID}}",
|
||||
"service_codes": [
|
||||
"PUBLIC"
|
||||
],
|
||||
"http_addr": "localhost:8080",
|
||||
"motd": [
|
||||
"Open source Winlink client - getpat.io"
|
||||
],
|
||||
"connect_aliases": {
|
||||
"telnet": "telnet://{mycall}:CMSTelnet@cms.winlink.org:8772/wl2k"
|
||||
},
|
||||
"listen": [ "ax25" ],
|
||||
"hamlib_rigs": {
|
||||
"et-rig": {
|
||||
"address": "localhost:4532",
|
||||
"network": "tcp"
|
||||
}
|
||||
},
|
||||
"ax25": {
|
||||
"engine": "agwpe",
|
||||
"beacon": {
|
||||
"every": 3600,
|
||||
"message": "Winlink P2P",
|
||||
"destination": "IDENT"
|
||||
},
|
||||
"agwpe": {"addr": "localhost:8000", "radio_port": 0}
|
||||
},
|
||||
"serial-tnc": {
|
||||
"path": "/dev/ttyUSB0",
|
||||
"serial_baud": 9600,
|
||||
"hbaud": 1200,
|
||||
"type": "Kenwood"
|
||||
},
|
||||
"ardop": {
|
||||
"addr": "localhost:8515",
|
||||
"arq_bandwidth": {
|
||||
"Forced": false,
|
||||
"Max": 500
|
||||
},
|
||||
"rig": "et-rig",
|
||||
"ptt_ctrl": true,
|
||||
"beacon_interval": 0,
|
||||
"cwid_enabled": true
|
||||
},
|
||||
"pactor": {
|
||||
"path": "/dev/ttyUSB0",
|
||||
"baudrate": 57600,
|
||||
"rig": "",
|
||||
"custom_init_script": ""
|
||||
},
|
||||
"telnet": {
|
||||
"listen_addr": ":8774",
|
||||
"password": ""
|
||||
},
|
||||
"varahf": {
|
||||
"host": "localhost",
|
||||
"cmdPort": 8300,
|
||||
"dataPort": 8301,
|
||||
"bandwidth": 2300,
|
||||
"rig": "",
|
||||
"ptt_ctrl": false
|
||||
},
|
||||
"varafm": {
|
||||
"host": "localhost",
|
||||
"cmdPort": 8300,
|
||||
"dataPort": 8301,
|
||||
"bandwidth": 0,
|
||||
"rig": "",
|
||||
"ptt_ctrl": false
|
||||
},
|
||||
"gpsd": {
|
||||
"enable_http": false,
|
||||
"allow_forms": false,
|
||||
"use_server_time": false,
|
||||
"addr": "localhost:2947"
|
||||
},
|
||||
"schedule": {},
|
||||
"version_reporting_disabled": false
|
||||
}
|
||||
@@ -0,0 +1,78 @@
|
||||
{
|
||||
"mycall": "{{ET_CALLSIGN}}",
|
||||
"secure_login_password": "{{ET_WINLINK_PASSWD}}",
|
||||
"auxiliary_addresses": [],
|
||||
"locator": "{{ET_GRID}}",
|
||||
"service_codes": [
|
||||
"PUBLIC"
|
||||
],
|
||||
"http_addr": "localhost:8080",
|
||||
"motd": [
|
||||
"Open source Winlink client - getpat.io"
|
||||
],
|
||||
"connect_aliases": {
|
||||
"telnet": "telnet://{mycall}:CMSTelnet@cms.winlink.org:8772/wl2k"
|
||||
},
|
||||
"listen": [ "ax25" ],
|
||||
"hamlib_rigs": {
|
||||
},
|
||||
"ax25": {
|
||||
"engine": "linux",
|
||||
"beacon": {
|
||||
"every": 3600,
|
||||
"message": "Winlink P2P",
|
||||
"destination": "IDENT"
|
||||
},
|
||||
"ax25_linux": {"port": "wl2k"}
|
||||
},
|
||||
"serial-tnc": {
|
||||
"path": "/dev/ttyUSB0",
|
||||
"serial_baud": 9600,
|
||||
"hbaud": 1200,
|
||||
"type": "Kenwood"
|
||||
},
|
||||
"ardop": {
|
||||
"addr": "localhost:8515",
|
||||
"arq_bandwidth": {
|
||||
"Forced": false,
|
||||
"Max": 500
|
||||
},
|
||||
"ptt_ctrl": true,
|
||||
"beacon_interval": 0,
|
||||
"cwid_enabled": true
|
||||
},
|
||||
"pactor": {
|
||||
"path": "/dev/ttyUSB0",
|
||||
"baudrate": 57600,
|
||||
"rig": "",
|
||||
"custom_init_script": ""
|
||||
},
|
||||
"telnet": {
|
||||
"listen_addr": ":8774",
|
||||
"password": ""
|
||||
},
|
||||
"varahf": {
|
||||
"host": "localhost",
|
||||
"cmdPort": 8300,
|
||||
"dataPort": 8301,
|
||||
"bandwidth": 2300,
|
||||
"rig": "",
|
||||
"ptt_ctrl": true
|
||||
},
|
||||
"varafm": {
|
||||
"host": "localhost",
|
||||
"cmdPort": 8300,
|
||||
"dataPort": 8301,
|
||||
"bandwidth": 0,
|
||||
"rig": "",
|
||||
"ptt_ctrl": false
|
||||
},
|
||||
"gpsd": {
|
||||
"enable_http": false,
|
||||
"allow_forms": false,
|
||||
"use_server_time": false,
|
||||
"addr": "localhost:2947"
|
||||
},
|
||||
"schedule": {},
|
||||
"version_reporting_disabled": false
|
||||
}
|
||||
Reference in New Issue
Block a user