synced 2026-09-17 15:41:44 -04:00
voacap - Added support for 20 watt power level
This commit is contained in:
@@ -2,7 +2,7 @@
|
||||
#
|
||||
# Author : Gaston Gonzalez
|
||||
# Date : 23 May 2023
|
||||
# Updated : 16 August 2025
|
||||
# Updated : 17 August 2025
|
||||
# Purpose : Offline HF prediction using voacapl
|
||||
source /opt/emcomm-tools/bin/et-common
|
||||
|
||||
@@ -74,7 +74,7 @@ usage() {
|
||||
echo " --rx-latlon LAT,LON Receiving station coordinates in decimal degrees"
|
||||
echo
|
||||
echo "Other options:"
|
||||
echo " -p POWER Output power [5|100|500|1500]"
|
||||
echo " -p POWER Output power [5|20|100|500|1500]"
|
||||
echo " -m MODE Mode [AM|CW|JS8|SSB]"
|
||||
echo
|
||||
|
||||
@@ -159,17 +159,23 @@ RK1=$( awk -v n1=$RK -v n2=180 -v n3=-180 'BEGIN {if (n1<n3 || n1>n2) printf ("%
|
||||
RLO=$( awk -v n1=$RK1 -v n2=0 'BEGIN {if (n1<n2) { n1=substr(n1,2); printf ("%7sW", n1); } else printf ("%7sE", n1);}' )
|
||||
|
||||
# Power settings
|
||||
# Use 80% of user-defined power and express in killiwatts
|
||||
# TODO: Make calculation dynamic.
|
||||
PWR=$power
|
||||
PW="0.0800"
|
||||
echo "TX Power: ${PWR} watts"
|
||||
if [ "$PWR" = "5" ]; then
|
||||
PW="0.0040"
|
||||
elif [ "$PWR" = "20" ]; then
|
||||
PW="0.0160"
|
||||
elif [ "$PWR" = "100" ]; then
|
||||
PW="0.0800"
|
||||
elif [ "$PWR" = "500" ]; then
|
||||
PW="0.4000"
|
||||
elif [ "$PWR" = "1500" ]; then
|
||||
PW="1.2000"
|
||||
else
|
||||
echo "Unsupported power level. Defaulting to 100 watts."
|
||||
fi
|
||||
|
||||