hamlib - Rolling back to hamlib 4.5 as version 4.6.5 seems to have introduced a bug in which the first client connection takes several seconds to initialize. This causes problems for some rig control clients such as JS8Call.
This commit is contained in:
@@ -2,7 +2,7 @@
|
||||
#
|
||||
# Author : Gaston Gonzalez
|
||||
# Date : 25 November 2022
|
||||
# Updated : 6 October 2025
|
||||
# Updated : 13 October 2025
|
||||
# Purpose : Install hamlib for rig control (rigctld)
|
||||
set -e
|
||||
trap 'last_command=$current_command; current_command=$BASH_COMMAND' DEBUG
|
||||
@@ -12,7 +12,11 @@ trap 'et-log "\"${last_command}\" command failed with exit code $?."' ERR
|
||||
. ../overlay/opt/emcomm-tools/bin/et-common
|
||||
|
||||
APP="hamlib"
|
||||
VERSION=4.6.5
|
||||
# The latest verion of Hamlib 4.6.5 has a problem with initial client
|
||||
# connections that can lead to rig control timeouts in applications like
|
||||
# JS8Call. Rolling back to version 4.5 which was stable.
|
||||
#VERSION=4.6.5
|
||||
VERSION=4.5
|
||||
APP_AND_VERSION="${APP}-${VERSION}"
|
||||
INSTALL_DIR="/opt/${APP_AND_VERSION}"
|
||||
LINK_PATH="/opt/${APP}"
|
||||
|
||||
Reference in New Issue